Your browser does not support script

 


ROUND HOLES FOR MORTAR JOINTS IN

Storm Manholes
  • For holes not intended for installation of field installed rubber connectors.

  • Both through holes and partial indentation knock out formers available.

  • Partial Hole/Knockouts must be ordered with attachment so they can be held tight to jacket wall.

  • Hole form diameters do not represent specific inside pipe diameter applications

  • Hole diameters shown below are measured at the face of the Hole Form or at the inside radius of the manhole.

MANHOLE
ID
WALL


24"
3"

Wall Taper


24"
4"

Wall Taper


24"
5"

Wall Taper


24"
6"

Wall Taper


36"
4"

Wall Taper


36"
5"

Wall Taper

Hole Dia.

                       

4"

                     
5" 5243 10.0            

 

     

7"

                 7364  10.6    

10"

 

 

                 

12"

12243 24.1  12244  5.4                

14"

                       

15"

       

 

             

16"

 

 

  16245  8.9

 

  16364 10.2

 

 

18"

18243 8.9 18244  10.6

 

  18246  9.8  18364  9.8 18365  8.5

20"

        20245  9.6    

 

 

 

 

21"

                21364 10.0 21365 10.0 

22"

       

 

     

22364

10.2

 

 

24"

        24245 7.8       24364  9.3 24365 10.0

26"

                       

28"

                    28365  10.0

30"

                       

32"

                       

34"

                       

35"

                       

36"

                       

38"

                       

40"

                       

42"

                       

44"

                       

45"

                       

48"

                       

52"

                       

55"

                       

58"

                       

62"

                       

64"

                       
72"                        
74"                        
76"                        

Calculation for determining largest opening of hole form WITH known wall taper:
((WALL TAPER X TANGENT) X 2) X WALL THICKNESS + FACE DIAMETER
This catalog page is available as an excel speadsheet to include large diameter opening of hole form.

  USE AND CARE GUIDE TECHNICAL INFORMATION

 

National Precast Concrete Association


1900 Ray Davis Boulevard - Seminole, OK - (405)382-7700 - Fax (405)382-7770

Toll Free: (800)876-2474 - email: Sales at Formcrete